Issue reported: Unable to update Boot Image getting error 0x80070003 or user is not able to schedule updates for OSD image.
Logs:
Mounting image at index 1. Image file=C:\ConfigMgr_OfflineImageServicing\ SB1003C6\BaseImage-Win7x64.wim, MountDirectory=C:\ConfigMgr_OfflineImageServicing\SB1003C6\ImageMountDir, ImageFileType=WIM, Mode=ReadWrite SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
Unable to mount image file SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
WIM::MountWIMImage returned code 0x80070003 SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
Failed to mount image SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
MountImage returned code 0x80070003 SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
Image Mount failed with error 3 SMS_OFFLINE_SERVICING_MANAGER 1/4/2016 8:35:58 AM 69084 (0x10DDC)
Solutions:
By seeing error found something wrong with path or not accessible or something wrong with ADK setup
Step 1: Verify permission all looks good.
Step 2: After we have repair ADK everything start working as normal .
Happy learning!!!
Haresh Hirani
Email: [email protected], [email protected]
Facebook https://www.facebook.com/Hiraniconfigmgr-120189361980772/
Follow us: https://www.linkedin.com/in/hiraniconfigmgr
Twitter: https://twitter.com/hiraniconfigmgr
X
0 Comments